Commercial cabling by industry

Every building type comes with its own codes, standards and schedule. Here is what changes the cable plan in each one, and where to read more.

The rules that shape each job

One line per industry: what drives the design, and the code or standard we plan around.

IndustryWhat drives the designWhat we plan around
Corporate officesAccess points, powered devices and occupied floorsTIA-568.1-E-1: two Category 6A cables per access point
Warehouses and distributionDistance, racking and roof height90 meter copper links, NFPA 13 clearance at ESFR sprinklers
ManufacturingNoise, dust, heat and vibrationTIA-1005-A MICE ratings, NEC Articles 500 to 506
Healthcare and clinicsWork in occupied patient areasASHE ICRA 2.0, ANSI/TIA-1179-B
Retail and restaurantsCard data, theft and opening hoursPCI DSS v4.0.1 Requirements 1 and 9
EducationFunding cycles and student safetyE-Rate Category Two, Alyssa’s Law in 13 states
HospitalityGuest rooms, phones and open-hotel workKari’s Law, RAY BAUM’S Act, ADA 806.3
Commercial real estateLease turnover and base building systemsNEC abandoned cable removal, IFC Section 510
A summary. Each industry page explains the rules and how they change the work.

Pick your building type

Each page covers the work, the rules and the scheduling that come with it.

Corporate offices

Cat6A for Wi-Fi 7, PoE bundles, conference rooms and refits on open floors.

Warehouses and distribution

Fiber to IDFs, access points per aisle and cameras on every dock door.

Manufacturing

MICE-rated cabling, distance from drives and separate OT networks.

Healthcare and clinics

ICRA precautions, medication room access and the healthcare cabling standard.

Retail and restaurants

PCI DSS in the closet, cameras that identify, and the same store many times.

Education

E-Rate Category Two, panic alarm wiring and phones that reach 9-1-1.

Hospitality

Room phones and Kari’s Law, ADA communication features and floor-by-floor work.

Commercial real estate

Abandoned cable, radio coverage testing, base building scope and conversions.

Buildings rarely fit one box

A tower can have shops on the ground floor, offices above and a hotel at the top. A distribution center has offices, and a hospital has a cafeteria and a parking garage. We scope each area by what happens in it, so the clinic floor gets ICRA precautions and the lobby retail gets its PCI DSS closet.

Wherever the building is, the metro rules still apply on top. Licensing and permits differ across the 20 metro areas we serve, and each metro page covers them.

For the work itself, start with structured cabling, security cameras or multi-site rollouts.

Common questions

My building type is not listed. Do you still work there?

If the work is commercial, send us the details. These eight pages cover the building types with the most specific rules, and the same approach applies to labs, government offices and other commercial buildings.

Do you work in residential buildings?

We do commercial work only. Apartment buildings come up as part of commercial projects such as office conversions and mixed-use buildings.

Do the industry rules replace local codes?

No. Industry standards sit on top of the state and city codes where the building is. Our metro pages cover those local rules.

Request a quote

Tell us the address, the building type and what you need installed. Drawings help but are not required.

Call 1-877-855-3865

Email

Free site assessments. Commercial work only.

We use your details only to reply to this request.