New construction and tenant fit-out cabling

Cablify carries the low-voltage scope on new buildings and tenant improvements: telecom rooms, pathways, data cabling, access control and camera cabling, worked to the general contractor’s schedule from rough-in to closeout.

Spec divisions
27 Communications, 28 Electronic Safety and Security
Firestopping
Tested systems to UL 1479 / ASTM E814
Inspections
Rough-in and above-ceiling
Closeout
Record drawings and test results

Who does what in the specifications

CSI MasterFormat splits building systems into divisions. Knowing which division a device sits in tells you which contractor carries it.

DivisionCoversWhere it meets our work
26 ElectricalPower, lighting, panels and, on many projects, conduit and back boxesPathways and boxes for our cable; power for racks, locks and cameras
27 CommunicationsStructured cabling, telecom rooms, racks, fiber and access point cablingOur core scope
28 Electronic Safety and SecurityAccess control, video surveillance and intrusion detectionCabling and device installation for security systems
Some owners require a BICSI Registered Communications Distribution Designer (RCDD) to approve the design, installation and documentation of the communications system.

Where low-voltage work lands in the schedule

Each stage has a point after which a mistake costs a wall or a ceiling. These are the stages we plan around.

Preconstruction

Submittals, product data and coordination of telecom room layouts, tray routes and device locations with the other trades.

Before mobilizing

Rough-in

Sleeves, back boxes, pathways and cable tray before walls close. In many jurisdictions the rough low-voltage inspection comes after framing, fireblocking and firestopping.

Walls open

Cable pull

Horizontal and backbone cable once pathways and the ceiling grid are in place, labeled as it is pulled.

Ceilings open

Above-ceiling inspection

Many building departments inspect wiring above the ceiling, including low-voltage cable, before ceiling tile goes in.

Before tile

Trim-out

Jacks, faceplates, devices, racks and patch panels after paint and finishes.

Finishes

Testing and closeout

Every link tested to the specification, then record drawings, test results and labels handed over.

Substantial completion

Firestopping is part of the scope

Building codes require cable passing through fire-rated walls and floors to be protected by firestop systems tested to UL 1479 or ASTM E814 and installed as tested. The tested system earns the rating, not any single product in it, so a sealant from one system and a sleeve from another does not pass.

The NEC repeats the rule for communications and fiber cable in Sections 800.26 and 770.26. We install listed systems at our penetrations and record each one on the drawings for the inspector.

Ground-up or tenant improvement

The same trade, two different jobs.

Ground-up buildings

We start with the entrance facility and the telecom rooms on each floor, so the backbone, the risers and the carrier handoff are planned before any horizontal cable. See structured cabling.

Tenant improvements

We start with what the base building already provides: riser space, the landlord’s telecom room and any cable left by the last tenant, which may have to come out. See cable removal.

Radio coverage for first responders is often in the same project. Our commercial real estate page covers the fire code rules.

Common questions

What is the difference between Division 27 and Division 28?

Division 27 covers communications: structured cabling, telecom rooms and fiber. Division 28 covers electronic safety and security: access control, video surveillance and intrusion detection.

When is low voltage installed during construction?

Pathways and boxes go in during rough-in while walls are open. Cable is pulled once pathways and the ceiling grid are in, and devices are trimmed out after finishes.

What is an above-ceiling inspection?

An inspection of the wiring above the ceiling, including low-voltage cable, done before ceiling tile is installed. Fixing a failed item after tile is in costs far more.

What does an RCDD do?

A BICSI Registered Communications Distribution Designer plans and designs telecommunications distribution systems. Some owners require one to approve the design, installation and documentation.