Cabling, Wi-Fi and access control for healthcare and clinics

Cablify installs network cabling, fiber, Wi-Fi, security cameras and access control in hospitals, outpatient clinics and medical offices, working in occupied buildings under the infection control precautions your team sets.

Infection control
ASHE ICRA 2.0, Classes I to V
Cabling standard
ANSI/TIA-1179-B, published 2023
Nurse call listing
UL 1069
Physical safeguards
HIPAA, 45 CFR 164.310

Above-ceiling work in an occupied building

Many healthcare facilities use the ASHE ICRA 2.0 matrix to set precautions for construction work, and it treats cabling as construction.

ICRA 2.0 sorts work into four types. Removing a ceiling tile to look is Type A. Installing conduit or cabling above the ceiling is Type B. Opening a new cable pathway or invasive electrical work above ceilings is Type C, as is any activity that cannot be finished in one shift.

The area’s patient risk group then sets the class of precautions. The same cable run can be Class II above an office and Class III above a patient room.

Patient risk groupType AType BType CType D
Low: non-patient care areasIIIIIIII
Medium: patient care supportIIIIIIIV
High: patient care areasIIIIIVV
Highest: invasive, sterile or highly compromised careIIIIVVV
From the ASHE ICRA 2.0 permit. Your infection prevention team sets the class for each area, and we work to it.

Class III

Dust control that can include hand-held HEPA vacuums, and a contained work area kept at neutral or negative pressure.

Above-ceiling cabling in patient care areas

Class IV

Critical barriers meeting NFPA 241, run to the deck above when ceiling tile is removed, with negative pressure from HEPA exhaust directed outdoors.

New pathways in patient care areas

Class V

Everything in Class IV, plus an anteroom for staging equipment, cleaning carts and workers.

Sterile and highly compromised care

Access to rooms, records and medications

The HIPAA Security Rule requires covered entities to limit physical access to their electronic information systems and the facilities that house them, while letting authorized people in. Its implementation specifications include a facility security plan, visitor control, and maintenance records for repairs to doors and locks.

For controlled substances, DEA rules for practitioners require a securely locked, substantially constructed cabinet. Card access and cameras on medication rooms add a record of who went in and when.

HHS proposed a Security Rule update in January 2025 that would require network segmentation and a network map. It is not final, and the federal regulatory agenda now lists final action for July 2027.

What we install

  • Badge readers, door contacts and request-to-exit devices on medication, records and server rooms
  • Cameras on entrances, pharmacies and supply rooms, with views kept out of patient care spaces
  • Separate, labeled patch fields for networks your IT team keeps apart
  • As-built drawings and port maps that match what is in the ceiling

Cabling built to the healthcare standard

ANSI/TIA-1179-B, published in 2023, is the telecommunications infrastructure standard for healthcare facilities. It covers cabling, topologies, distances, pathways and spaces. The previous edition, in 2017, made Category 6A the minimum for twisted-pair horizontal cabling.

Nurse call equipment is listed to UL 1069, and NFPA 99 covers nurse call systems in healthcare facilities. We run the cabling and pathways your listed nurse call vendor specifies.

Patient rooms

Drops for workstations on wheels, TVs, nurse call and bedside devices.

Nurse stations

Dense drops for workstations, printers, phones and label printers.

Imaging and labs

Fiber and Cat6A to equipment rooms and analyzers.

Wi-Fi

Access points placed for phones, pumps and carts as well as staff laptops.

Clinics and medical offices

Smaller sites have fewer rules on paper but the same patients in the waiting room.

After-hours installs

Work scheduled outside clinic hours so exam rooms stay open.

Occupied clinics

Guest Wi-Fi

A separate network for patients in waiting rooms, kept off the clinical network.

Every site

Front desk and check-in

Drops for check-in kiosks, card readers and label printers.

Reception

Multi-site groups

The same drop counts, labels and closeout package at each location in a practice group.

Clinic networks

Large medical centers anchor several of our metros, including Houston, Boston, Baltimore and Minneapolis-St. Paul.

Common questions

Can you work in an occupied hospital?

Yes. We work to the infection control risk assessment and permit your facility issues, including barriers, HEPA vacuums and negative pressure where the class calls for them, and schedule around patient care.

Why does above-ceiling cabling need ICRA precautions?

Opening the ceiling can release dust into patient areas. Under ICRA 2.0, installing cabling above the ceiling is Type B work, and the patient risk group of the area decides the class of precautions.

Do you install nurse call systems?

We install the cabling and pathways. The nurse call equipment itself is listed to UL 1069 and supplied and programmed by your nurse call vendor.

Do you work in clinics and medical offices?

Yes, from single offices to multi-site practice groups, with work scheduled outside clinic hours.

Request a quote for a healthcare site

Send the address, the type of facility and the areas involved. If your facility issues ICRA permits, tell us the class.

Call 1-877-855-3865

Email

Free site assessments. Commercial work only.

We use your details only to reply to this request.